Cdn PT1A - 4-Ev ENt Timer & Clock EN Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Relais Cdn PT1A - 4-Ev ENt Timer & Clock EN. CDN PT1A - 4-Ev ENt Timer & Clock EN User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 3
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Features
4 channels
Programmable
Dual function
Memory
Counts up & down in 4 channels separately
or simultaneously
Clock
Stopwatch
Loud and long alarm
Individual channel sounds
Stop and restart
Counts up after zero
ABS plastic
Sliding mode switch
International time
4-way mounting: pocket clip/magnet/stand/loop
Battery and instructions included
Note: Remove sticker from display before use.
Note: In the following instructions, names of the control
buttons are shown in CAPS. Function information that appears
on the display is shown in BOLD CAPS.
Battery Installation
Replace battery when LCD becomes dim or alarm
level declines.
1. Remove battery door by turning it
counterclockwise.
2. Install LR44 battery with positive (+) side up.
3. Replace battery door and lock it by turning
it clockwise.
Operating Instructions
A. Set Clock
1. Select CLOCK mode with sliding mode switch.
12:0000AM will appear after inserting battery.
2. Press and hold ENTER approximately
2 seconds until the display ashes.
3. Press CLEAR to toggle between 12-hour,
AM/PM time, and 24-hour, international time.
4. Press HR, MIN and SEC to enter the desired
time. Press and hold button for fast advance.
5. Press ENTER to exit. The PT1A will
automatically exit 3 seconds after the last entry.
B. Count Down
1. Select COUNT DOWN mode with sliding mode
switch. COUNT DOWN will appear on the
display.
2. Press HR, MIN and/or SEC to enter the desired
time. Press and hold button for fast advance.
3. Press START/STOP to start the count down.
Press START/STOP button to interrupt the
count. Press START/STOP button again to
resume the count.
4. When the desired time is reached, alarm will
sound and the timer will start to count up the
overtime. OT (OverTime) and COUNT UP
will appear on the display while TIME’S UP
ashes.
5. Press START/STOP to stop the alarm. The
alarm will stop automatically after 60 seconds
while the count up continues.
Model: PT1A
4-Event Timer & Clock
Counts 100 hours by minutes & seconds
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - 4-Event Timer & Clock

Features• 4 channels• Programmable• Dual function• Memory• Counts up & down in 4 channels separately or simultaneously• Clock• Stopwatch•

Page 2 - Care of Your Product

6. Press CLEAR to reset to 0:0000.Note: The timer will retain any time showing on the display when the sliding mode switch is moved to another positio

Page 3

© 2006 Component Design Northwest, Inc. Made in China CD9999108en - 11/06 EHC 614 885 -2497      

Commentaires sur ces manuels

Pas de commentaire